| Control relays |
| |
Current, Single Phase |
| |
|
IMCA |
AC-DC |
Multifunction, 12 rages for under or over current in one unit |
0,5mA - 10A |
| |
|
ILUA |
DC |
Current loop relay |
4 - 20mA |
| |
|
ILUB |
DC |
Current loop relay w. precision adjustment |
4 - 20mA |
| |
Current, Single Phase, with through hole for CT |
| |
|
IMAA |
AC |
Current, Earth leakage and Differential current
Multifunction with 12 current ranges in one unit |
5mA - 100A |
| |
|
IADA |
AC |
Current detecting relay with delayed drop out. 12VDC supply |
9 - 16VDC |
| |
|
DDCA |
DC |
Current, Earth leakage and Differential current. 6 current settings |
5 - 200mA |
| |
|
DDCB |
DC |
Current, Earth leakage and Differential current. 6 current settings (Ext. coil) |
5 - 300mA |
| |
|
DDEA |
DC |
Current, Earth leakage for DC unearthed systems, Asym leakage |
0,2 - 30mA |
| |
|
DDEB |
DC |
Current, Earth leakage for DC unearthed systems, Asym & Sym leakage |
0,2 - 30mA |
| |
Current, single Phase, with voltage compensated setpoint |
| |
|
IUAB |
AC |
AC current relay, monitoring up to 10 loads, error if one or more fails |
0,2 - 2,5A |
| |
Voltage, Single Phase |
| |
|
UMCA |
AC-DC |
Multifunction, 11 ranges in one |
50mV - 500V |
| |
|
UAWA |
AC |
Window Voltage relay. Individual low & high voltage setting |
100 - 415V |
| |
Voltage, Single Phase, incl. frequency control |
| |
|
UFWA |
AC |
Window voltage & frequency relay. Individual low & high voltage setting |
100 - 415V |
| |
Voltage, 3 phase 4 wire |
| |
|
PNDA |
AC 4w |
Phase under voltage & phase sequence |
100 - 415V |
| |
|
PNDI |
AC 4w |
Phase under voltage & phase sequence with true time delay |
100 - 480V |
| Battery Control relays |
| |
|
BMCA |
DC |
Battery low voltage monitoring relay. For 12V, 24V, 48V & 110V batteries.
Replacement for BVCA, BVCB, BVCC |
8 - 80V |
| |
|
BMCD |
DC |
Battery high/low voltage monitoring relay. For 12V, 24V, 48V & 110V batteries
Replacement for BVCD, BVCE, BVCF |
8 - 180V |
| |
|
BMWB |
DC |
Universal DC voltage relay. Individual Low & High voltage plus hysteresis setting |
12,5 - 340V |
| |
|
BVSA |
DC |
Battery symmetry monitoring relay |
12, 24 and 48V |
| |
|
BMSA |
DC |
Battery symmetry monitoring relay with digital setting and display
Symmetry setting: 1 to 20% of cell voltage |
24 - 256V |
| |
|
BRIA |
DC |
DC ripple relay. Setting: 0.4 – 6.4% ripple |
18 - 340V |
| Phase, Neutral & Ground monitoring. 3, 4 or 5 wire |
| |
|
PMSA |
AC |
RMS Neutral to Ground plus RMS Phase to Neutral or RMS Phase to phase |
50 - 830V
suppl.: 18-288V |
| Phase failure relays, 3 or 4 wire |
| |
Voltage and asymmetry |
| |
|
PADA |
AC 3w |
Unbalance & Balanced under & over voltage |
100 - 480V |
| |
|
PADI |
AC 3w |
PADA with true time delay |
100 - 480V |
| |
|
PANA |
AC 4w |
PADA with test for Neutral |
100 - 480V |
| |
|
PANI |
AC 4w |
PADA with test for Neutral and true time delay |
100 - 480V |
| |
Voltage and asymmetry + phase rotation |
| |
|
PAHA |
AC 3w |
Phase rotation w. 2 relays, Unbalance & Balanced under & over voltage |
100 - 480V |
| |
|
PAHI |
AC 3w |
PAHA with true time delay |
100 - 480V |
| |
|
PAMA |
AC 4w |
PAHA with test for Neutral |
100 - 480V |
| |
|
PAMI |
AC 4w |
PAHA with test for Neutral and true time delay |
100 - 480V |
| |
Voltage and asymmetry + Frequency |
| |
|
PAFA |
AC 3w |
Frequency 50, 60 and 400Hz, Unbalance & Balanced under & over voltage |
100 - 480V |
| |
|
PAGA |
AC 4w |
PAFA with test for Neutral |
100 - 480V |
| |
Voltage and asymmetry + Frequency + phase rotation |
| |
|
PAFB |
AC 3w |
PAFA with test for Phase rotation |
100 - 480V |
| |
|
PAGB |
AC 4w |
PAFA with test for Phase rotation and Neutral |
100 - 480V |
| Engine & generator relays |
| |
Starter inhibit |
| |
|
FXAA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
12V |
| |
|
FAAA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
24V |
| |
Over speed |
| |
|
FXBA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
12V |
| |
|
FABA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
24V |
| |
Starter inhibit and over speed |
| |
|
FRAA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
12V |
| |
|
FRBA |
Freq. |
Frequency range from 10 to 5120Hz. Transformer, Namur or optocoupler input |
24V |
| |
Synchronizer |
| |
|
SYND |
AC 2w |
Synchronization of grid and generators |
100 - 500V |
| |
|
SYPD |
Bus 3w |
Optional 96x96 Panel indicator to SYND |
Bus 3 wire |
| Isolation amplifiers |
| |
Multi function, Volt and mA input |
| |
|
AISA |
DC |
Programmable: 8 input and 8 output volt/mA ranges. Includes power supply |
24 - 440V |
| |
Multifunction, mV input |
| |
|
AISB |
DC |
Programmable: 4 mV input and 8 volt/mA output ranges. Includes power supply |
24 - 440V |
| |
Multifunction, Volt input |
| |
|
UISA |
DC |
Programmable w.16 input volt ranges and, 8 output V/mA ranges. Incl. power supply |
24 - 440V |
| |
Volt in and current loop out |
| |
|
UIDA |
DC |
2 input ranges: 4.8 - 24V and 6 - 30V to current loop |
4 - 20mA |
| |
Current loop isolator |
| |
|
AITA |
DC |
Current loop. 3 loops 4 to 20mA. Loop powered |
4 - 20mA |
| |
|
AITB |
DC |
Current loop. 1 loop 4 to 20mA. Loop powered |
4 - 20mA |
| Transducers |
| |
Current |
| |
|
IAMA |
AC |
Dual range: 1 & 5Aac in to 6 standard V/mA output ranges |
24 - 440V |
| |
|
IAMB |
AC |
Dual range: 1 & 5Aac in to 4 - 20mA current loop out |
24 - 440V |
| |
Voltage |
| |
|
UAMA |
AC |
Dual range: 250 & 500Vac in to 6 standard V/mA output ranges |
24 - 440V |
| |
|
UAMB |
AC |
Dual range: 250 & 500Vac in to 4 - 20mA current loop out |
24 - 440V |
| |
Frequency |
| |
|
FAMA |
Freq. |
Min. & Max. range specified from 1 to 5000Hz. 8 V/mA output ranges |
24 - 440V |
| Design of housing for 35/45/55 and 22,5 mm housing |
| |
|
DEH |
|
Cabinet drawings |
|